Babies Soothers Test Clamp Series(EN 1400/EN 14350) (Model:SFT S1-2130)

Conforms To

EN-1400, EN14350-1,EN14372, EN12586


Babies Soothers Test Clamp Series(EN 1400/EN 14350) (Model:SFT S1-2130)


Application

Whenever children andinfants are concerned, product safety is required to be maintained at thehighest standards.

The SFT S1-213X Babies Soothers Test Clamp Series designaccording to EN1400-2, can be performed using to material test machine.

Conforms To

EN-1400, EN14350-1,EN14372, EN12586

Specifications

A, SFT S1-2130 Indentor

EN14350-1 Figure8 and 9, EN14372 Figure5

EN 1400:2013 clause 5.3 (Figure 6) Sample indentor (exclude cutting board)

1) The clamp must using a universeal-testing machine.

2) The clamp can move left-rightfor different test part request

B, SFT S1-2131 Tear resistance test offlexible knob

EN1400:2013 Clause 9.4Figure 26

1)    The clamp must using auniverseal-testing machine.

2) The back face of theshield shall be supported as in Figure 26. The support shall be close to theknob, plug and or cover, but without making contact. Certain soothers fittedwith rings require slots in the soother support in order to achieve a good fiton the back of the shield (see Figure 26).

Cut the tip off the teat at 5 mm to 10 mm from theteat/shield junction. Place a 5 mm diameter rod with a flat end into the teatuntil it rests on the plug or the combined plug and cover. Apply a force of (90± 5) N at a crosshead speed of (10 ± 1) mm/min and maintain for (10 ± 0,5) s.

If the soother is fitted with a separate plug andknob or cover then all parts shall be tested. Apply the force to the undersideof the knob or cover e.g., by drilling a hole in the centre of the plug toallow access for the test rod, or by such other means as the design of thesoother might allow.

In cases where a 5 mm diameter rod is notsatisfactory, an alternative rod having a round or flattened cross section of asuitable size shall be used.

C, C-1: Bite endurance jaws-- The clamp must using a universal-testing machine.

EN1400:2013 Clause 5.5Figure 8

1) The clamp must using a universeal-testing machine.

2) Test procedure: Place the soother whose teat is to be tested between the stainless steeljaws as shown in Figures 10 and 11, such that the full force is applied by thebiting edges, between the teat and the shield. Apply a minimum load of (200 ±10) N to hold the soother. Apply a maximum load of (400 ± 10) N and minimumload of (200 ± 10) N as the upper jaw cycles up and down 50 times at acrosshead speed of (10 ± 1) mm/min.

C-2: Bite endurance jaws----needs to be used on the platform of the push-pull dynamometer.

Test procedure reference C-1 test procedure

D, SFT S1-2133 Endurancetest (ring tester )

EN1400:2013 Figure D.2  

The clamp must using a universeal-testingmachine.

E, SFT S1-2134 3-points bending tester

EN14372Figure 6, the clamp must using a universal-testing machine.

F, SFT S1-2135 Fixture forsecurity/retention test (optional adjustable)

EN14350-1 Figure11

1)    The clamp must using auniverseal-testing machine.

2)    Test procedure:

G, SFT S1-2136 Fixing devices for tensiletests

EN1400:2013 ANNEX D FigureA.1 (just first picture) , The clamp must using a universal-testing machine.

H, SFT S1-2137 Flexibility Test of Straw

EN14350-1Figure12

1)    The clamp must using auniverseal-testing machine.

2)    Test procedure:

I, SFT S1-2138 Test penetration gauge

EN 1400-1 Figure 5,6,7 & 8

J, SFT S1-2139 Cutting board (Hardness 70 D)

EN1400:2013 clause 5.4 Figure 7, EN14372

K, SFT S1-2140 Shield template for pacifier

EN1400:2013 clause 5.1 (Figure 5)

L, SFT S1-2150 Impact Test Device

EN1400:2013clause 5.6 Figure 9, EN1400-2 clause6.2.1 Figure 6

Plate Size:300(l)x300(w)x16(h)mm

Adjustable height: 0-300mmor

0-400mm (Customizable)

Diameter of the hammer:80±2mm

Weight of the hammer:1±0.02kg

M, SFT S1-2141Dia. 4mm Rod (Long 150mm)

EN12586 clause 5.1.10, GB28482 Clause 5.2.3

N, SFT S1-2142 Dia. 12mm Rod (Long 150mm)

  EN12586clause 5.1.10, GB28482 Clause 5.2.3

O, SFT S1-2143 Dia. 14mm Rod (Long 150mm)

  EN1400-1, GB28482 Clause 5.2.3

1-Dia. 14mm rod  

P, SFT S1-2144 Dia. 5.5mm Rod (Long 150mm)

  EN14372

Q, SFT S1-2145 Steel Sphere (a set of 4units)

EN1400:2013 clause 5.2 (Table 1)

Test Spheres A,B,C andD, shall be made from stainless steel

R, SFT S1-2146 Compression Board (SHORE A 40+/-5)

  EN12586 clause 6.1.5.2

S, SFT S1-2083 Rattle TestFixture

  EN1400:2013 Clause 5.7 Figure 10 and Figure11, ASTM F963 Fig20 and Fig21; EN71 8.16

T, SFT S1-2147 Template C

  EN1400:2013 Clause5.7 Figure 12, EN12586

U, SFT S1-2148 Dia.25mm Template

  EN12586

V, SFT S1-2149 45 degree /90 degrees bottle leakagetest stand

Ordering Information

SFT S1-2130 Indentor

SFT S1-2131 Tear resistance test of flexible knob

SFT S1-2132 Biteendurance jaws

SFT S1-2133 Endurancetest(ring tester )

SFT S1-2134 3-points bending tester

SFTS1-2135 Fixture forsecurity/retention test (optional adjustable)

SFTS1-2136 Fixing devices for tensile tests

SFT S1-2137 FlexibilityTest of Straw

SFT S1-2138 Test penetration gauge

SFT S1-2139 Cutting board

SFT S1-2140 Shield template for pacifier

SFTS1-2150 Impact Test Device

SFTS1-2141 Dia. 4mm Rod

SFTS1-2142 Dia.12mm Rod

SFTS1-2143 Dia.14mm Rod

SFTS1-2144 Dia.5.5mm Rod

SFTS1-2145 Steel Sphere (a set of 4units)

SFTS1-2146 Compression Board (SHORE A 40+/-5)

SFTS1-2083 Rattle Test Fixture

SFTS1-2147 Template C

SFTS1-2148 Dia.25mm Template

SFTS1-2149 45 degree /90 degrees bottle leakage test stand


[Return]