UL Surface Ceiling Temperature Test Apparatus (Model: SFT S2-1813)

Conforms To

UL1598, UL1278, UL1450, UL8750,UL935,UL153 etc.

UL CeilingTemperature Test Apparatus according to UL1598 clause 19.10 and Figure 19.10.1,UL1993 Figure 9.2 and 9.5.2.


UL Surface Ceiling Temperature Test Apparatus (Model: SFT S2-1813)


Application

UL CeilingTemperature Test Apparatus according to UL1598 clause 19.10 and Figure 19.10.1,UL1993 Figure 9.2 and 9.5.2.

Conforms To

UL1598, UL1993

Specifications

SFT S2-1813 UL Ceiling Temperature Test Apparatus

A, 1218mm front and back × 1218mm, 12mm thick plywood

B, 2 inches (50.8 mm) wood on both sides × 4 inches (101.6 mm)

C, Wood at both ends is 1 inch (25.4mm) × 4 inches (101.6 mm)

D, Internal support wood is 2 inches (50.8 mm) × 4 inches (101.6 mm)

E, The 8-angle junction box with standard 4 x 1-1/2 inch imported fromthe United States and UL certification is installed inside

F, The wiring consists of a white and black 14AWG wire and a 16AWG orthicker wire connected to the junction box for grounding

G, Two layers of glass fiber with a thickness of about 89mm arevertically laid in the ceiling, with a thermal resistance value of Rsi 1.4 to1.9, which is directly in contact with the Bagua board and completely laidaround the metal conduit

REMARK : The bottom of the test ceiling shall be at least 1.8meters from the ground. Please ensure that the floor height of the test room isat least 2.3 meters, and at least 0.6 meters from any wall or other obstacles

OrderingInformation

SFT S2-1813UL Ceiling Temperature Test Apparatus