Conforms To
IEC60884-1Figure18 & 19, VDE0620, AS/NZS3112, BS1363, CEE007
Socket & Plug Strength Tester (Model:SFT S2-1305B)
Application
Theconstruction of accessories shall allow for easy insertion and withdrawal ofthe plug, and prevent the plug from
working outof the socket-outlet in normal use. Interlocked accessories are tested in theunlocked position.
Complianceis checked, for socket-outlets only, by a test to ascertain that the max forcenecessary to withdraw the
test plugfrom the socket-outlet is not higher than the force specified in standard; by atest to ascertain that the min
forcenecessary to withdraw a single pin gauge from the individual contact assemblyis not lower than the force
specified instandard.
Conforms To
IEC60884-1Figure18 & 19, VDE0620, AS/NZS3112, BS1363, CEE007
Specifications
A, The Max. Socket output should comply with therequirements in table 16: the standard prescribed by the maximum pull output(main weight, additional weight, clamping device, the unification of the totalforce of test plug), on the test plug, plug from the socket out.
B, The Minimum Socket output should comply withthe regulations in table 16: pull pulled the minimum standard output (whichmeet the requirements of this standard test pin< single pin >, the totalquality should be equal to the specified value in the table) of the gauge isplugged into an outlet in the insert each individual sets, The test pin gaugeis applied gently, and care is taken not to knock the assembly when checkingthe minimum withdrawal force. The gauge shall not fall from the contactassembly within 30 s.
C, Structure: clamping device installed underthe roof of A D, main weight and weights set E, F this device within theframework of 550 mm high, distance between two pillar axis is 150 mm, see Figure18.
D, Dimensions: W*D*H=195mmx195mmx640mm
E, Weight: 14kg (exclude weights etc.)
Ordering Information
SFT S2-1305BSocket & Plug Strength Tester (Max. and Min. Force)