ConformsTo
IEC60598-2-13 Figure3
Ground recessed luminaires tester (Model:SFT S2-1212)
Application
The device is used to check Ground recessed luminaires tester, ground recessed luminaires should beable to withstand the required minimum static load, and should be able toaccept cornering , braking and acceleration forces generated by the tire.
According to IEC60598-2-13 Figure 3 standard request, theequipment shall comply with the pressure change rate ≤ 5000N/min , rubber pressure headdiameter required 50mm, 60-70 Shore A hardness , thickness is 50mm; The test systemwith numerical scale , multiple -precision pressure sensor sampling , controlis closed loop.
ConformsTo
IEC60598-2-13 Figure3
Specifications
A, Pressure range: 0— 20kN (adjustablesettings)
B, Dwell time : Shear time keeping 5-10s / anti- static time 60s
C,Extrusioncycles: 20times
D, Pressure Fluctuation: <1.0%
E, Power sources : hydraulic power
F, High pressure gear pump : Displacement 1,400 rpm , flow 2.8 l / min
G, Machine Material:high quality aluminum alloy, carbon steel polished handle
H, Lamp support Dimensions: Φ50-Φ300mm
I, Pressure measurement : precision pressure sensor
J, Sensor accuracy :± 0.1%
K, Outer Dimensions : D600×W800×H1700(mm)
L, Power supply: 380V~ 50Hz <1000W
M,Weight: 180KG
OrderingInformation
SFT S2-1212Ground recessed luminaires tester