Luminaires & Lamp Funcation Test IEC60598

Home > Products > E&E Safety Equipments > Luminaires & Lamp Funcation Test IEC60598

Ground recessed luminaires tester (Model:SFT S2-1212)

ConformsTo

IEC60598-2-13 Figure3


Ground recessed luminaires tester (Model:SFT S2-1212)


Application

The device is used to check Ground recessed luminaires tester, ground recessed luminaires should beable to withstand the required minimum static load, and should be able toaccept cornering , braking and acceleration forces generated by the tire.

According to IEC60598-2-13 Figure 3 standard request, theequipment shall comply with the pressure change rate ≤ 5000N/min , rubber pressure headdiameter required 50mm, 60-70 Shore A hardness , thickness is 50mm; The test systemwith numerical scale , multiple -precision pressure sensor sampling , controlis closed loop.

ConformsTo

IEC60598-2-13 Figure3

Specifications

A, Pressure range: 0— 20kN (adjustablesettings)

B, Dwell time : Shear time keeping 5-10s / anti- static time 60s

C,Extrusioncycles: 20times

D, Pressure Fluctuation: <1.0%

E, Power sources : hydraulic power

F, High pressure gear pump : Displacement 1,400 rpm , flow 2.8 l / min

G, Machine Material:high quality aluminum alloy, carbon steel polished handle

H, Lamp support Dimensions: Φ50-Φ300mm

I, Pressure measurement : precision pressure sensor

J, Sensor accuracy :± 0.1%

K, Outer Dimensions : D600×W800×H1700(mm)

L, Power supply: 380V~ 50Hz <1000W

M,Weight: 180KG

OrderingInformation

SFT S2-1212Ground recessed luminaires tester