ConformsTo
IEC 60529, 60068-2-68 La2, 60598-1, BS EN 60529, GB7000; GB4208
Dust Chamber (Model:SFT S2-1055)
Application
Dust chamber is intended for determining the degree of protectionagainst harmful deposits of dust (IP5X) and against ingress of dust (IP6X). Itis designed in compliance with IEC standards (e.g. IEC 60529,)..
IP5X Dust protected means to Ingress of dust is not entirelyprevented, but it must not enter in sufficient quantity to interfere with thesatisfactory operation of the equipment; complete protection against contact
IP6X Dust tight means to No ingress of dust; complete protection against contact
This productis applicable for the dust proof and resistant test of various auto componentsand parts including lamps, electric dust proof sheath, steering system and locketc.
Instrument
The SFT S21055 DustChamber, the test cabinet with funnel ismade of stainless steel, doors are made of glass. It stands on four heavy dutyscrew legs which enable leveling of chamber. Housing is made of steel sheet,structure lacquered.
The SFT S21055 DustChamber works by aconcentration of the sand and dust blower to promote a flow rate of blowing thesurface of the test sample, to evaluate the test sample (device) or fullyexposed to dust, sand dry atmospheric dust particles under the action ofosmotic effect defensive ability, defensive grit abrasive or blocking effect ofability and potential storage and the ability to run.
Features
--- Stainless steelinner tank and outer box steel plate spray paint;
---Self-contained cabinet with large viewing window with LED lighting;
-- Stainlesssteel shelf for place test sample;
--- Touch Screen Controller Control , PLC control
--- Test time can be set: total testtime, dust blowing time, gap time, vibration time, gap time, vacuum time,blower frequency and other test parameters directly on the touch screen;
--- Duct ingenious structure, temperature, dust concentration smalldeviation;
--- The bottom of the chamber is afunnel-shaped device, and an electromagnetic vibrator is installed on thefunnel wall to meet the needs of sand and dust recovery. The pipeline isequipped with a dust heating and drying device to meet the normal operation ofdust in a humid state;
--- Doorsare made of glass with double anti-aging silicone rubber seal, easily observethe test sample test status, equipped with a manual wiper;
--- Pneumatic vibration mode, theair pressure is steplessly adjustable, and the air pressure has a bufferfunction;
-- Vacuum system configuration:vacuum pump, flow meter, vacuum negative pressure gauge, pressure regulatingvalve, filter;
- IP6X vacuuming; flow control andvacuum pressure difference control are independently adjusted, and the negativepressure difference is kept accurate and stable during testing. It is equippedwith two flowmeters to increase the range;
--- Sample test power supply(built-in dustproof socket), separated sample power supply can be controlled onand off;
--- Sand dust air circulationdevice: circulating air duct and ventilator;
--- Function: blowing dust, dust:for clearance, periodic tests;
--- Added sample power preheating function,for example: during lamp test, the lamp is required to be energized and
preheated to a stable state before the dust test isperformed. After the preheating time is completed, the dust test
will start automatically, so that it can becompleted directly in the sand and dust chamber at one time;
--- Dust air circulation device:circulating air duct and fan ;
--- Safety include Ground faultprotection, Leakage / circuit protection, Overload fuse protection, Audio alarmprotection and Over temperature protection.
Conforms To
IEC 60529, 60068-2-68 La2, 60598-1, BS EN 60529, GB7000; GB4208
Specifications
A, Workroom Dimensions:1000mm×1000mm×1000mm(other size option)
B, Temperaturerange: room temperature +15℃~ +45℃
C, Relative humidity inthe chamber: <25%<>
D, Temperaturetolerance : ≤±2℃
E, Test dustconcentration: 2-4 Kg/m³
F, Wind speed(air speed): ≤2m/s(vertical air flow from top tobottom, non-laminar flow)
G, Pressureof the pumping system: the vacuum does not exceed 20kpa
H, Pumping pressure: normal pressure~ -2kPa, -5kPa, -10kPa can be adjusted
I, Pumping speed: 60-6000ml/min canbe adjusted (60~600 l/min, 0.6~6 l/min two flow meters)
J, Mesh Diameter: 50um
K, Wire Spacing: 75um
L, Testtime: 0-99999Min60S (can be set, stop automatically when the time is reached)
M, Blowingdust on: 0-99999Min60S (can be set)
N, Dustblowing stop: 0-99999Min60S (can be set)
O, Innerwall dust removal vibration turned on: 0-99999Min60S (can be set)
P, Innerwall dust removal vibration stop: 0-99999Min60S (can be set)
Q, Negativepressure open: 0-99999Min60S (can be set)
R, Negativepressure stop: 0-99999Min60S (can be set)
S, Samplepower on: 0-99999Min60S (can be set)
T, Samplepower off: 0-99999Min60S (can be set)
U, Power-onpreheating before the sample test: 0-99999Min60S (can be set)
V, Fanoperating frequency: 10-50Hz (can be set)
W, Dimensions: W1620mm*D1230mm*H1950mm
X, Weight: 200KG
Ordering Information
SFT S2-1055Dust Chamber
Include : 15KG standard talcum powder
Standard screen