Conforms To
IEC60695-11-5(2016),IEC60695-2-2, IEC60745-1, IEC60335-1,IEC60950-1, IEC60598-1, IEC60065
Needle Flame Tester REV2 (Model:SFT F3-3030)
Application
Insulation and combustible materialsused inside electrical and electronic products may propagate flames when afailed component ignites, which may develop into a fire that endangers the safetyof operators and product operation. The Needle Flame Tester is used to assessthe fire hazard of such component materials. The test is performed to determinethat the test flame does not cause ignition of parts, or that a combustiblepart ignited by the test flame has a limited duration of burning or a limitedextent of burning, without spreading fire by flames or burning or glowingparticles falling from the test specimen.
Conforms To
IEC60695-11-5(2016),IEC60695-2-2, IEC60745-1, IEC60335-1,IEC60950-1, IEC60598-1, IEC60065
Specifications
A, Power Supply : 220V 50Hz or 110V 60Hz
B, Needle Burner : stainless steel bore: ф 0.5mm±0.1mm, Outer diameter<ф>35mm.
C, Burner Angle:vertical (for adjusting and measuring flame height) and tilting 45° (for test)
D, Flame TemperatureSensor: Type K (NiCr /NiAl) thermocouple (ф0.5mm,-200~1100 C°)
E, Standard CopperBlock : 4mm±0.01mm, weight:0.58g±0.01g.ASTM-B187(Cu-ETP UNS C 11000)
F, Time forTemperature to Increase : From 100°C±5°C to 700°C±3°C; 23.5s±1.0s
G, Flame Height : 12mm±1mm (adjustable)
H, Height Gauges: 11mm, 13mm, 6mm, 5mm, 8mm
I, Flame ImpingementTime : 5s, 10s, 20s, 30s, 60s, 120s(preset)
J, Operation Manner : Touch screen controller
K, Piloted pavelayer: Thick 10mm white pine wood, covered 12g/m 2 ~ 30g/m 2 standard crepepaper, 200mm ± 5mm below the flame application point
L, Gas Supply : Butane gas, min. 95% purity (prepare by customer)
M, Effective TestVolume : >0.5m³, black interior
N, Vent Pipe Diameter : 100mm
O, Outer Dimensions : W*D*H=1180mm*550mm*1150mm
P, Weight : 80KG
Ordering Information
SFT F3-3030 Needle Flame Tester -specify 220V 50Hz or 115V 60Hz