ConformsTo
IEC60884 clause23.2 (table 18), VDE0620 clause23.2(table18)
Flexible Cable Torque Tester (Model:SFT S2-1304)
Application
FlexibleCable Torque Tester is conforms to IEC60884-1 clause 23.2.After testing cordretention. the flexible cable is subjected for 1 min to a torque as specifiedin following table:
Torque testvalues for cord anchorages
Rating of plug or portable socket-outlet Flexible cable (number of cores × nominal cross-sectional area in mm2)
2*0.5 2*0.75 3*0.5 3*0.75 (2 or more)*1
Up to and including
16A and 250V 0,10Nm 0.15Nm 0.15Nm 0.25Nm 0.25Nm
16A and above 250V \ \ \ \ 0.35Nm
Above 16A \ \ \ \ 0.425Nm
After thetests, the flexible cable shall not have been displaced by more than 2 mm. Forrewirable accessories, the end of the conductors shall not have movednoticeably in the terminals; for non-rewirable accessories, there shall be nobreak in the electrical connections.
Formeasurements of the longitudinal displacement, a mark is made on the flexiblecable at a distance of approximately 20 mm from the end of the specimen or theflexible cable guard, before it is subjected to the pull.
If, fornon-rewirable accessories, there is no definitive end to the specimen or theflexible cable guard, an additional mark is made on the body of the specimen.
Thedisplacement of the mark on the flexible cable in relation to the specimen orflexible cable guard is measured while the flexible cable is subjected to thepull.
ConformsTo
IEC60884 clause23.2 (table 18), VDE0620 clause23.2(table18)
Specifications
A, Weight:2N/3N/5N/7N/8.5N*1unit
C, Dimensions : W*D*H=48cm *22cm* 80cm
D, Weight : 25KG
OrderingInformation
SFT S2-1304 FlexibleCable Torque Tester