E&E Flammability Test

Home > Products > E&E Safety Equipments > E&E Flammability Test

Horizontal Vertical Flame Chamber (50W+500W) (Model:SFT F3-3010)

Conforms To

UL94:Tests for Flammability of PlasticMaterials for Parts in Devices and Appliances

IEC 60695-11-10:Fire hazard testing : Test flames -50 W horizontal and vertical flame test methods

IEC 60695-11-20: Fire hazard testing: Test flames -500 W flame test methods

IEC 60695-11-4:Fire hazard testing: Test flames -50 W flames-Apparatus and conformational test method

IEC 60695-11-3:Fire hazard testing: Test flames -500 W flames-Apparatus and conformational test method

Horizontal Vertical Flame Chamber (50W+500W) (Model:SFT F3-3010)


Application

The Horizontal Vertical Flame Chamber is designed for the flammabilitytesting of plastic materials used in consumer electric devices and appliances.The chamber is constructed of stainless steel with a black interior and largesliding window for easy viewing.

The SFT F3-3010 Horizontal Vertical Flame Chamber includes a fullyadjustable specimen support and a precision metered gas burner. this testingdevice is used to simulate the influence of the early-stage flame upon the firearound the electrical products and electronic products in order to assess thefire hazard level through the simulation technology. It is mainly used for thehorizontal and vertical flammability test on the relative combustioncharacteristics of the samples of the plastics and other non-metallic materialparts, solid materials and the foam plastics with the apparent density not lessthan 250kg/m3 measured by the method specified in ISO845.

Conforms To

UL94:Tests for Flammability of PlasticMaterials for Parts in Devices and Appliances

UL94HB: Horizontal Burning Test

V-0,1,2: 20mm Vertical Burning Test

94-5VA,B: 500W(125mm) Vertical Burning Test

94VTM-0,1,2: Thin Material Vertical BurningTest

94HBF,94HF-1,2 : Horizontal Burning Foamed MaterialTest

IEC 60695-11-10:Fire hazard testing : Test flames -50 W horizontal and vertical flame test methods

IEC 60695-11-20: Fire hazard testing: Test flames -500 W flame test methods

IEC 60695-11-4:Fire hazard testing: Test flames -50 W flames-Apparatus and conformational test method

IEC 60695-11-3:Fire hazard testing: Test flames -500 W flames-Apparatus and conformational test method

ASTM D 635:Standard Test Method for Rate of Burning and/orExtent and Time of Burning of Plastics in a Horizontal Position

ASTM D3801:Standard Test Method for Measuring the ComparativeBurning Characteristics of Solid Plastics in a Vertical Position

ASTM D4804: StandardTest Method for Determining the Flammability Characteristics of Nonrigid SolidPlastics

ASTM D4986:Standard Test Method for Horizontal BurningCharacteristics of Cellular Polymeric Materials

ASTM D5048: Standard Test Method for Measuring the ComparativeBurning Characteristics and Resistance to Burn-Through of Solid Plastics Usinga 125-mm Flame

ISO 9773:Plastics -- Determination ofburning behaviour of thin flexible vertical specimens in contact with asmall-flame ignition source

Specifications

Flame power

50W(V-0、V-1)

500W(5VA、5VB)

Conforming to standards

UL94、IEC60695-11-4、IEC60695-11-10

UL94、IEC60695-11-3  、IEC60695-11-20

Timing device

9999X0.1s

9999X0.1s

Combustion angle

0°, 20°, 45°

0°, 20°, 45°

Height of flame

Total height 20±2mm

Inner flame 40±2mm total height 125

Distance for temperature measurement

10±1mm

55±1mm

Standard for blast burner

IEC60695-11-4, UL94

IEC60695-11-3, UL94

Temperature testing

MAX 1100°C, thermocouple: type K

MAX 1100°C, thermocouple: type K

Gas flow rate

105 ± 5 ml/min

965±30ml/min

Water column height

<10mm<>

125±5mm

Time of calibration

Time of rise from 100±5°C to 700±3°C  is 44±2S

Time of rise from 100±5°C to 700±3°C  is 54±2S

Accuracy of flow rate

1%

1%

Weight of copper block

1.76 g ± 0.01 g (before drilling)

10 ± 0 .05g (before drilling)

Gas Supply

Methane, min 98% purity (prepare by client)

Volume of box

0.75m3, black interior

Outer Dimensions

W*D*H=1320mm*760mm*1300mm

Weight

150KG

OrderingInformation

SFT F3-3010 Horizontal Vertical Flame Chamber (50W+500W) - specify 220V 50Hz or 115V 60Hz