News & FAQ

FAQ

Home > News & FAQ > FAQ

IEC 62368-1, 2 Ed. (2014-02) List Apparatus

Add time:2018-04-23   Clicks:7150   [Return]

IEC 62368-1, 2 Ed. (2014-02)

TESTING AND MEASURING EQUIPMENT/ALLOWED SUBCONTRACTING

R = Required to be at Lab

IEC 62368-1 test equipment has been identified for usein the sub-grouped below:

RA = Required for Amplifiers; in addition to RB,required for apparatus with audio amplifiers (audio power > 0,5 Watts)

RB = Required Basic - test and measurement equipment required for all apparatus

RC = Required for Cable distribution system; in addition to RB, required for apparatus with connection(s) to a cabledistribution system

RSH = Required for SHredder; in addition to RB, required for shredder

RT = Required for Telecom; in addition to RB,required for apparatus with connection(s) to a telecommunication network

RV = Requiredfor CRT / Plasma/LCD or other Video equipment in addition to RB required fortesting  CRT Cathode ray Tubes/ picturetubes,  plasma/LCD or other video apparatus

S = May be Subcontracted

SP = SPecialized testing facility

W = May be Witnessed at MTL

                                                                                                                         

Clause

62368-1 1Ed.

Measurement/testing

Testing / measuring equipment / material needed

Subcontracting

4.7

Equipment for direct insertion in to mains socket-outlets

Test equipment (see Fig. 11 of IEC 60065)

RB

4.8

Coin/button cell batteries

30 N ± 1N applied by rigid test finger (Figure V.2); test  hook (Figure 20)

RB

Crush Test –  300 N ± 5N; flat  surface measuring 100 mm by 250 mm; timer

RB

5.2.2.2

Steady- state voltage and current limits

Amp- and voltmeter suitable for the current and waveform, frequency  meter

Measuring instruments in according IEC 60990: 1999 Figure 4 and 5

RB

5.2.2.4

Single pulse limits

Oscilloscope

RB

5.3.2.

Accessibility to electrical energy sources and safeguards

Blunt probe  of Figure V.3

RB

5.4.1.10

Thermoplastic parts on  which conductive metallic parts are directly mounted

Vicat test B 50 of ISO 306

S

Ball pressure test  apparatus according to IEC 60695-10-2
 Oven at least 125ºC

RB

5.4.1.4, 9.2.5

Maximum operating temperatures for materials, components and systems

Voltage  supply

Single phase  voltage supply systems/variability/adequacy

RB


Three phase  voltage supply systems

S


Temperature  (rise)

Temperature  recorder (multi-channel)

RB


Thermocouples

RB


Winding  resistance (normally > 1,0 W 2-wire, 4-wire <1,0 W ).

RB


Voltage

Voltmeters  (ac/dc)

RB


High voltage  meter (probe)

RB


Current

Currents  (ac/dc)

RB


Loading

Loads  (resistive)

RB


5.4.2, 5.4.3, 5.4.4

Clearances, creepage distance, solid insulation

Oscilloscope

RB

Dial gauge or  caliper

RB

Micrometer

RB

Pins etc.  With different diameters

RB

Microscope

RB

Impulse test  generator circuit 1 of Table D.1.

Impulse test  generator circuit 2 of Table D.1.

impulse test  generator circuit 3 of Table D.1

RT

S

RC


Test  equipment for tracking index per IEC 60112

S

Mandrel  (figure 25 to 28), metal foil, equipment suitable for electrical strength test loads

Stop watch, weight

S

5.4.5.2

Antenna  terminal insulation

Insulation  resistance meter (500V > 4 M), Impulse test generator circuit 1 of Table D.1

RC

5.4.1.5.3

Thermal cycling test procedure

Full draught  oven (± 2ºC)

Cooling  facility (0º±2 C)

S

5.4.8

Humidity  conditioning

Chamber RH(  93 ± 3)%, 20...30  ° C

RB

Chamber RH (93  ± 3)%, (40 ± 2)°C

RB

Extra large  environmental testing chamber

SP

5.4.9

Electrical  strength test

Test  Instrument/equipment according to Figure 29 for electric strength

RB


Test  Instrument/equipment according to Figure 29 for electric strength (of  solid/thin sheet insulation).

S


5.4.10

Safeguards  against transient voltages from external circuits

Blunt probe  figure V.3

RB

5.4.11

Separation  between external circuits and earth

Non-inductive  Resistor 5000,  Ampere meter

RB

5.5.2.2

Capacitor  discharge

Measuring  instrument with input impedance 100MW or more in parallel with an input capacitance of 25pF or  less

RB

Annex T

Annex  T

Force of 10 N ± 1  N

RB

5.6.4.1

Resistance  of protective conductors and their terminations

High current  source with a voltage not exceeding 12 V,

RB


Determination  of the overcurrent protective device and circuit (Annex R)

Source with  at least 1500A short circuit

S


5.7

Prospective touch  voltage, touch current and protective conductor current

Networks in  according IEC 60990:1999 figures 4 and 5;

Amp-meter

RB

6.2.2

Power source  circuit classification

Watt meter,  variable resistor load, stop watch

RB

6.4.8.3.3

Top openings  and top openings properties

Cheesecloth bleached cotton cloth 40g/m2

RB

8.2

Mechanical  energy source classifications

Scale up to  25kg

RB

8.5.4.2

Equipment  having an electromechanical device for destruction of media

Test probe  (jointed) of Annex V (figure V.1 and V.2) and

wedge probe  V.4

Force 45N and  90 N with wedge probe

RB

RSH

RB

RB

8.5.5.2.

High pressure lamps

Dark sticky  mat, , magnified glass with a resolution of 0,1 mm

RB

8.6.2

Static stability for floor  standing equipment

Inclined  plane 15°

(Inclined  plane 10°)

RB

Force 250N/
 Test tool 800Nwith a flat surface 12,5cm by 20cm

RB

8.6.4

Glass slide  test

Glass plate,  10°

RB

8.6.5

Horizontal  force test

Inclined  plane 15°, force 100N

RB

8.7

Equipment mounted to a wall or ceiling

Several  weights, timer

Torque gauges

RB

8.8

Handle strength test method

75mm width,  several weights, scale, timer

RB

8.9

Wheels or  casters attachment requirement

Force 20N, stop watch

RB

8.10

Carts, stands  and similar carriers

Force up to 440 N with a circular plan surface Æ 30mm, , stop  watch,

RB


8.11

Mounting  means for rack mounted equipment

Several weights, timer

RB

8.12

Telescoping  or rod antennas (Annex T.11)

test tool for  applying torque up to 0,6Nm, test tool for applying force 20N, stop watch

RA

10

Radiations

Laser  (including laser diodes)

Several  special equipment for laser classification(IEC 60825-1)

S


Light  emitting diodes (LEDs)

Several  special equipment for LED classification(IEC 62471:2006)

S


X-ray

Radiation  monitor, ionizing

chamber type  with an effective area of 1 000 mm²

S


Effect of UV  radiation on materials (Annex C)

Test  equipment according to ISO 178, 179, 180, 527 and 8256 and according ISO 4892  series.

S


Human  exposure to UV radiation (Annex C)

Measuring  equipment  according to IEC 62471

S


Acoustics

Special  equipment for acoustic measurements (EN50332-1/-2)

S


Annex B.2.5

Input test

Amp-meter  suitable for the current and waveform, power meter, voltmeter,

RB

Variable loads

RB

Signal  generator in acc. IEC 60107-1:1997

RV

Annex B.3.2

Covering of  ventilation openings

piece of card  with 200 g/m² density

RB

Annex E

Test  conditions for equipment contain audit amplifiers

Testing box

RA


Signal  generator (sinus) 1kHz or alternative
 Band-pass filter for wide-band noise measurement,
pink noise signal  generator

RA


Annex F.3.10.2

Durability

water/piece  of cloth/ timer

RB

Annex F.3.10.3

Durability

Petroleum  spirit (85% n-hexane), (CAS# 110-54-3)

RB

Annex G.5.4.5.3 G.5.4.6.3  G.9.3 S.3.1 S.3.2

Alternative  test method

Cheesecloth (bleached cotton cloth 40g/m2), Wrapping Tissue (12g/ m2 – 30g/m2)

RB

Annex G.7

Mains supply  cords

Test equipment according IEC 60227

S

Appropriate weights

RB

Torque meter or equivalent

RB

Annex G.9

IC current  limiters

resistor: 100 Ω +/- 5 Ω

capacitor: 425 μF +/- 10µF

inductance: 0,35 mH +/- 0,1mH; <1 Ω   dc resistance

Oven with a range of -30°C+/-2°C   up to 70°C +/-2°C

50°C± 2°C for 10 min; followed by 10 min at 0°C± 2°C with a 5 min  period of transition from one state to the other

S

Annex G.10

Test for  resistor serving as safeguard

Impulse test  generator circuit 1 of Table D.1.

Impulse test  generator circuit 2 of Table D.1.

impulse test  generator circuit 3 of Table D.1

Test  according to IEC 60068-2-78

RT

S

RC
 S

Annex G.13.6.2

Test method and compliance criteria

Full draught oven  (± 2ºC)

S

Annex G.13.6.2

Abrasion  resistance test

Scratch test  device with steel pin

S

Annex G.15

Pressurized  liquid filled components

Hydrostatic  pressure

Hydrostatic pressure test  device

S

Tubing  and fittings compatibility test

Tensile strength test  device in acc to ISO 527 series

S

Vibration  test

Vibration generator  (0,35mm/10Hz-55Hz-10Hz) IEC 60068-2-6

S

Annex  G.16

Discharge  function

Chamber RH( 93 ± 3)%,  20...30ºC, (40 ± 2)ºC

Impulse test  generator circuit 2 of Table D.1.

S

Annex H

Criteria for telephone ringing signals

5 000Ω resistor

RT

Annex J

Insulated winding wires for use without  interleaved insulation

Test equipment according  to IEC 60851-3,IEC 60851-5 and IEC

60851-6

S

Annex  M.4.2, M.4.4.4

Charging voltage and current

Oven

S

Annex M.6.2

Leakage current

Insulation resistance  meter

S

Annex M.8.2

Protection   against internal ignition from external spark sources – Spark Test

Equipment according to  IEC 60896-21:2005 Sub cl. 6.4

S

Annex P.2

Safeguards against entry of solid foreign  objects

Suitable tool (or tools)  to simulate a straight metal object, 1mm in diameter, length up to 13 mm

RB

Annex. P.4

Metallized coatings and adhesives securing  parts

Oven

S

Annex S

Tests for resistance to heat and fire

Needle flame test  apparatus acc. to IEC 60695-11-5:2004

SP

Distillate fuel oil as described in Annex S.3.2

S

500W flame test apparatus  in acc. to IEC 60695-11-20:1999

SP

Cheesecloth (bleached cotton cloth 40g/m2), Wrapping Tissue (12g/ m2 – 30g/m2)

RB

Annex

T.2 - T.4

Steady force test

10N ± 1N

Test finger  (figure V1 or V2 unjointed , 30N± 3N)

Test tool  100N± 10N with a circular plan surface Æ 30mm
 Stop watch

RB

Annex T.5

Steady force test, 250 N

Test tool  250N± 10N with a circular plan surface Æ 30mm.

RB

Annex T.6

Enclosure impact test

Æ 50mm/500g± 25g steel ball

RB

Annex T.7

Drop test

Hard wood  13mm on 18mm ± 2mm plywood,  two layers. ruler up to 1000 mm ± 10mm

RB

AnnexT.8

Stress relief test

Measuring  equipment according to IEC 60695-10-3 or Oven 70K over normal temp.

RB

Annex T.9

Impact Test  

steel ball 50mm, approx  500g., Fragmentation test  Centre punch and a square of 50 mm side

RB

Annex U

Mechanical  strength of CRTs and protection

against the  effects of implosion

Test  equipment acc.IEC 61965

Scale,  diamond stylus, cooling liquid, timer

S

Annex V.1.2

Test method 1  – Surfaces and openings tested with jointed test probes

Figure V.1 –  Jointed test probe for equipment likely to be accessible to children

Figure V.2 –  Jointed test probe for equipment not likely to be accessible to children

RB

Annex V.1.3

Test method 2  – Openings tested with straight unjointed test probes

Figure V.1: straight  unjointed version of the respective test probe applied with a force of 30 N.

RB

Annex V.1.4

Test method 3  –
 Plugs, jacks, connectors

Figure V.3 –  Blunt probe

RB

Annex V.1.5

Test method 4  –
 Slot openings

Figure V.4 –  Wedge probe

RSH

Annex V.1.6

Test method 5  – Terminals intended to be used by an ordinary person

Force 1 N  ± 0,1N

Terminal  probe IEC 61032:1997 figure 4

RB







Note: Thepresence of equipment alone does not indicate a satisfactory situation.Assessors must evaluate the equipment design, calibration, uncertainty anddocumentation to ensure compliance with the directions of the standard. Therequirements of ISO/IEC 17025 regarding validation are applicable, as the testsof this standard are not standardised tests.